Skip to main content
  • Research article
  • Open access
  • Published:

Trends of blood pressure and heart rate in normal pregnancies: a systematic review and meta-analysis

Abstract

Background

Current reference ranges for blood pressure and heart rate throughout pregnancy have a poor evidence base.

Methods

This is a systematic review and meta-analysis. We included studies measuring blood pressure or heart rate from healthy pregnant women within defined gestational periods of 16 weeks or less. We analysed systolic blood pressure, diastolic blood pressure and heart rate by gestational age. We assessed effects of measurement year and method.

Results

We included 39 studies undertaken in 1967–2017, containing 124,349 systolic measurements from 36,239 women, 124,291 diastolic measurements from 36,181 women and 10,948 heart rate measurements from 8317 women. Mean (95% CI) systolic blood pressure was lowest at 10 weeks gestation, 110.4 (108.5, 112.3) mmHg, rising to 116.0 (113.6, 118.4) mmHg at 40 weeks, mean (95% CI) change 5.6 (4.0, 7.2) mmHg. Mean (95% CI) diastolic blood pressure was lowest at 21 weeks gestation, 65.9 (64.2, 67.7) mmHg; rising to 72.8 (71.0, 74.6) mmHg at 40 weeks, mean (95% CI) change 6.9 (6.2, 7.5) mmHg. Mean (95% CI) heart rate rose from 79.3 (75.5, 83.1) beats/min at 10 weeks to 86.9 (82.2, 91.6) beats/min at 40 weeks gestation, mean (95% CI) change 7.6 (1.8, 13.4) beats/min. Studies using manual measurement reported higher diastolic blood pressures than studies using automated measurement, mean (95 CI) difference 4.9 (0.8, 8.9) mmHg. Diastolic blood pressure increased by 0.26 (95% CI 0.10–0.43) mmHg/year. Including only higher-quality studies had little effect on findings, with heterogeneity remaining high (I2 statistic > 50%).

Conclusions

Significant gestational blood pressure and heart rate changes occur that should be taken into account when assessing pregnant women. Commonly taught substantial decreases in blood pressure mid-pregnancy were not seen and heart rate increases were lower than previously thought. Manual and automated blood pressure measurement cannot be used interchangeably. Increases in diastolic blood pressure over the last half-century and differences between published studies show contemporary data are required to define current normal ranges.

Study registration

PROSPERO CRD42014009673

Peer Review reports

Background

Heart rate and blood pressure are key vital signs for the assessment of pregnant women [1, 2]. Our understanding of the normal thresholds for these vital signs underpins their use. Many modern clinical guidelines do not reference the sources of their normal vital sign ranges [3,4,5]. Others refer to an obstetric physiology textbook, which references data from small individual studies published between 1970 and the mid-1990s [6]. Core textbooks commonly suggest a mid-pregnancy dip of around 5 mmHg for systolic and 10–15 mmHg for diastolic blood pressure along with a progressive rise in heart rate ranging from 10 to 20 beats/min [7,8,9]. Where referenced, these texts rely on the same physiology textbook [6] or small individual studies from over 30 years ago [10]. The changes in vital signs that occur in pregnancy are known to complicate the recognition of deterioration [11]. However, we could not identify a clinical guideline or Modified Early Obstetric Warning Score (MEOWS) [2] that took account of expected gestational changes in vital sign physiology. MEOWS use the perceived normal thresholds to determine whether a woman requires review. However, the thresholds used are based on clinical consensus [4, 12]. Small changes in thresholds make substantial differences to the ability of clinical scores to identify physiological deterioration [13, 14]. Evidence-based normal values that take into account changes during pregnancy are therefore required. We carried out a systematic review and meta-analysis to establish whether gestation-specific normal ranges for heart rate and systolic and diastolic blood pressure can be produced from available studies of participants that were “healthy” at recruitment. We planned to investigate the effects of year of measurement, method of measurement (for blood pressure) and parity on vital signs.

Methods

This systematic review follows the Meta-analysis Of Observational Studies in Epidemiology (MOOSE) [15] and Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) [16] guidelines (Additional file 1). We registered the review (PROSPERO: CRD42014009673) and published the protocol [17].

We included cross-sectional, case-control or longitudinal studies containing at least fifty participants and where measurements were taken by a healthcare professional.

We included studies containing blood pressure or heart rate measurements from pregnant women recruited as “healthy”. We defined “healthy” as women not known to have conditions likely to affect blood pressure or heart rate at the point of first measurement, according to inclusion and exclusion criteria described in Table 1. We included studies where participants recruited as healthy subsequently developed conditions potentially affecting blood pressure or heart rate. In studies where these participants’ data were presented separately, we extracted vital sign measurements for both groups. We excluded data where an intervention potentially affecting these vital signs was studied. We included baseline measurements prior to an intervention. We excluded data from subgroups selected at recruitment on the basis of characteristics or medical diagnoses (Additional file 2: List S1); we extracted data from control groups of “healthy” pregnant women in these studies. We excluded studies where the gestational age at which measurements were taken was not defined to 16 weeks or less.

Table 1 Inclusion and exclusion criteria

We set out to include measurements of all six vital signs recommended for clinical assessment (systolic blood pressure, diastolic blood pressure, heart rate, oxygen saturation, respiratory rate and/or temperature), made antepartum, intrapartum or postpartum [17]. We have restricted this report to blood pressure and heart rate data measured in the antepartum period, as we found little data for other vital signs or time periods.

Search strategy

With a trained librarian, we searched MEDLINE, Embase and CINAHL, from inception until February 2018. We also searched reference lists and contacted field experts. Where required data were not presented or were presented in a form we could not extract, we contacted the original authors by e-mail. We used both MeSH and free-text terms. We did not restrict the year or language of publication. The complete search strategy has been described previously [17]. Additional file 2: Table S1 details the MEDLINE search strategy.

Two reviewers (LL and RP) independently screened retrieved titles and abstracts to exclude studies that clearly fell outside the scope of the review, such as foetal or animal studies. Two reviewers (PW and LM) independently screened the remaining studies by title, then by abstract and finally by full text against the inclusion and exclusion criteria (Table 1). Where reviewers disagreed, the study proceeded to the next screening stage.

Data extraction

Two reviewers (LL and RP) independently extracted study data onto a piloted spreadsheet (Microsoft Excel). Disagreements were automatically highlighted and resolved by recourse to the original papers or in consultation with a medical statistician (JB), intensive care specialist (PW) or obstetric physician (LM), as required.

For each study, we extracted information about the study (year of data collection and publication, study setting, country of study, data collection schedule), measurements (method, subject position, details of measurement device) and participants (age, weight, body mass index (BMI), ethnicity, reason for measurements, parity, number of gestations, pregnancy dating method). For each period of pregnancy defined in a paper, we extracted information about the sample size and minimum and maximum gestational age, together with reported summary statistics for blood pressure and heart rate. We used Engauge Digitizer, https://sourceforge.net/projects/digitizer/works (open source software) to extract data from graphs if the underlying data were not presented and we could not obtain it from the authors.

Assessment of bias

Two reviewers (LL and RP) independently undertook quality assessment in line with QUADAS (Quality Assessment of Diagnostic Accuracy Studies)-2 [18], adapted from the methodology of Ioannou et al. [19] following pre-determined rules (Additional file 2: Table S2). We assessed studies over two domains: study design and reporting methods. We scored statistical methods within these two domains, taking account of differing study designs. Each methodological criterion was scored as either “high” or “low” risk of bias. For each of the two domains, the overall quality score for each study was defined as the percentage of “low risk of bias” marks over the total number of criteria. We assessed the effects of only including studies scoring 50% or more on mean estimates of heart rate and blood pressure and on heterogeneity between studies.

Summary measures

Principal summary statistics were mean and standard deviation for each measure of heart rate and blood pressure, along with sample size. Where mean and standard deviation for blood pressure and heart rate were not reported, we approximated these assuming a normal distribution (with no skewness), in line with previous descriptions of vital sign measurement distributions [20]. Where multiple measurements were reported on the same day for the same participants (e.g. blood pressure measured in the sitting and lying positions), we selected a single data point using pre-specified rules [17]. We assigned the development status of a study country using the Human Development Index (2015) [21].

Where the gestational age associated with each data point was reported as a mean or median gestational age, we used this for the analysis. Where the gestational age associated with each data point was reported as a range, we used the mid-point of the range. Gestational age measured using ultrasound measurement of the foetal crown-rump length before 14 weeks gestation was our preferred assessment method [22].

Where the sample size associated with each data point was reported, we used this for the analysis. For studies where the sample size was reported only at baseline, we took the sample size associated with each data point to be the baseline sample size, assuming no dropouts or loss-to-follow-up.

Where characteristics of women (weight, BMI, age, parity) were reported at multiple time points (e.g. pre-pregnancy, at recruitment and/or at delivery), we used the value closest to recruitment. Where the mean values of the characteristics of the sample of women associated with each data point were reported, we used this for analysis. For studies where the characteristics of women were only reported for the entire sample of women recruited, and not for the sample at each time point, we used entire sample values, assuming no dropouts or loss to follow-up. Where only median values were reported, we used these instead of the mean values, assuming normal distributions of characteristics (with no skewness).

The study year was taken to be the last year of recruitment to the study or the year of publication where this was not reported.

Synthesis of results

To analyse trajectories of changes in blood pressure and heart rate, we adapted the method for meta-analysis of longitudinal studies proposed by Ishak et al. [23, 24] Ishak conducted a meta-analysis of longitudinal studies reporting data at a series of fixed time points, using study summary statistics. Linear mixed effects models were used to take account of correlations in longitudinal data. We adapted Ishak’s general multivariate model to conduct a meta-analysis of studies which report data at different time points, whilst still accounting for correlations between data points within studies and between studies (our “longitudinal model”). The time points in our analysis are the different values of gestational age. All data points from an individual study were included. We used a random coefficients model that allows for an arithmetic description of the relationship between the measurement of interest and gestational age [25]. The models were built up based on polynomials of gestational age by adding higher order polynomials, first as fixed effects, and then as random coefficients. Decisions on which terms to include were based on AIC and BIC (Akaike and Bayesian Information Criterion)—measures of assessing model fit whilst accounting for the number of parameters [26, 27]. To assess the additional benefit of higher order fixed effects terms, we fitted models based on maximum likelihood (ML) estimation; whereas to assess the benefit of higher-order random effect terms, and to fit the final model, we undertook restricted maximum likelihood estimation (REML). Each observation was weighted according to the study reported standard error. To account for the correlation of observations within a study, a spatial power covariance structure was used, which allows for the irregular nature of time between measurements [28].

We undertook pre-specified secondary analyses to investigate the effects of method of measurement (manual vs. automated), year of data collection and parity on systolic and diastolic blood pressure. We added these covariates to the model as fixed effects. We added method of measurement and year of measurement simultaneously as we expected them to be related. To assess the effect of parity, where possible, we separated data into nulliparous and multiparous groups. Otherwise, we entered parity into the model as the proportion of multiparous mothers. We did not undertake secondary analyses of heart rate, as the limited study numbers would have resulted in imprecise results.

Additionally, we pooled data for each trimester from each included study in a random effects analysis to generate Forest plots for each vital sign. Trimesters were defined as trimester 1 from 0+ 0 to 12+ 6 weeks; trimester 2 from 13+ 0 to 25+ 6 weeks; trimester 3 from 26+ 0 to 36+ 6 weeks and full term from 37+ 0 weeks to delivery [29]. Where data were reported for subgroups within a single study, for example for nulliparous and multiparous women, a weighted mean and standard error of the mean were calculated. Where more than two data points for a single trimester within a study were reported, the same women would be included in both data points, so the mean of the data points was calculated. The standard error of the mean was calculated assuming a correlation between measurements on the same patient of 0.7. This was considered reasonable considering how close in time the measurements were. The weighted mean of the gestational age for the data points was calculated.

We estimated the pooled weighted mean and 95% confidence intervals where the weight of an individual study was inversely proportional to the sum of the variance (SE2) of the study mean and the between-study variance. To estimate the spread of vital sign data in an individual study setting, we computed 95% prediction intervals from the random effects analysis, according to the methodology presented by Riley et al. [30] We determined heterogeneity using the I2 statistic (range 0–100%).

We performed a pre-specified sensitivity analysis excluding outlying studies (with means lying outside of the predictive interval). We also performed an additional sensitivity analysis excluding studies scoring less than 50% on quality assessment.

As the studies included in the review did not have a comparative design, we could not assess publication bias. However, selective reporting was assessed as part of the quality assessment.

Statistical analyses were undertaken using StataCorp. 2015 (Stata Statistical Software: Release 14. College Station, TX: StataCorp LP) or SAS software (Version 9.3, SAS Institute Inc. SAS).

Results

Database screening identified 1897 publications. We identified a further 14 publications from reference lists or expert knowledge. We included 39 studies from 20 countries meeting our pre-specified criteria, Fig. 1. Detailed reasons for exclusion are shown in Additional file 2: Table S3.

Fig. 1
figure 1

Study identification and selection

The included studies are summarised in Additional file 2: Table S4. We extracted blood pressure data from 34 studies. We extracted heart rate data from 13 studies. Studies came from 20 different countries, 17 high-development countries and three middle- or low-development countries. One (Russian) study was not reported in English [31].

We included 394 summary measurements of blood pressure, representing 124,349 systolic measurements from 36,239 women and 124,291 diastolic measurements from 36,181 women. The 23 longitudinal studies reported measurements of blood pressure from 33 separate groups of women [32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54]. Longitudinal studies varied in the number of time points at which a group had blood pressure measured (median 4 time points, range 2 to 35). A further 11 studies reported cross-sectional measurements [31, 55,56,57,58,59,60,61,62,63,64]. Two of these studies reported multiple cross-sectional measurements [56, 61]. The remaining studies reported measurements at a single time. A manual sphygmomanometer was used in fifteen studies [34, 35, 37,38,39, 41, 44, 45, 47, 49, 53, 57, 58, 62, 64]. An automated blood pressure monitor was used in thirteen studies [32, 33, 42, 43, 48, 50,51,52, 54,55,56, 59, 61]. Six studies did not report the measurement methodology [31, 36, 40, 46, 60, 63].

We included 34 summary measurements of heart rate, representing 10,948 heart rate measurements from 8317 women. The five longitudinal studies reported measurements from seven separate groups of women [32, 42, 48, 65, 66]. Summary measurements were reported at between 3 and 8 (median 4) time points per group. A further eight studies reported cross-sectional measurements of heart rate at a single time point [31, 57, 59, 63, 64, 67,68,69]. The method of heart rate measurement was reported as electrocardiography (ECG; 5 studies, 8 time points) [57, 64, 66,67,68], echocardiography (echo; 1 study, 2 time points) [69], finger arterial pressure sensor (1 study, 4 time points) [48], radioulnar pulse wave monitoring (1 study, 8 time points) [65], reading from an automated blood pressure (BP) monitor (2 studies, 4 time points) [42, 59] or not specified (3 studies, 16 time points) [31, 32, 63].

Quality assessment scores ranged from 5.6 to 84.2% (median 44.4%, where 100% is a good score). Additional file 2: Figure S1 summarises the score per assessment criterion. Individual paper scores are shown in Additional file 2: Table S4. Common reasons for scoring poorly included not sufficiently defining the population under study (28 studies), not defining gestational age using ultrasound measurement of crown-rump length before 14 weeks (26 studies) and not describing/using measurement devices ratified for use in pregnancy (30 studies). Of the 13 studies that used automated methods of blood pressure measurement, three stated that they used machines validated for use in pregnancy [42, 48, 59]. Five studies reported that the measurement device was calibrated prior to the study taking place (all manual sphygmomanometer methods) [37, 39, 44, 62, 64]. The method of blood pressure measurement was not specified in six studies [31, 35, 36, 40, 46, 69]. Use of an appropriately sized BP cuff was reported in 13 studies [33, 37, 38, 42,43,44,45, 47, 49, 54, 58, 61, 62].

Both systolic and diastolic blood pressure changed significantly across pregnancy (for combined manual and automatic readings) when modelled using our longitudinal model (Fig. 2). Systolic blood pressure was lowest at 10 weeks gestation, mean (95% confidence intervals, CI) 110.4 (108.5, 112.3) mmHg, rising to 116.0 (113.6, 118.4) mmHg at 40 weeks gestation; a change of 5.6 (95% CI 4.0, 7.2) mmHg from 10 to 40 weeks (p < 0.001). Mean (95% CI) diastolic blood pressure was 67.1 (65.4, 68.7) mmHg at 10 weeks gestation. Mean (95% CI) diastolic blood pressure was lowest at 21 weeks 65.9 (64.2, 67.7) mmHg, rising to 72.8 (71.0, 74.6) mmHg at 40 weeks; a change of 6.9 (95% CI 6.2, 7.5) mmHg from 21 to 40 weeks (p < 0.001). Mean (95% CI) heart rate rose from 79.3 (75.5, 83.1) beats/min at 10 weeks to 86.9 (82.2, 91.6) beats/min at 40 weeks; a change of 7.6 (1.8, 13.4) beats/min from 10 to 40 weeks (p = 0.014), Fig. 3. Though all longitudinal studies showed heart rate to increase across pregnancy, three relatively small studies showed a small drop in heart rate at the end of pregnancy [32, 48, 65].

Fig. 2
figure 2

Mean BP (solid black line), with 95% CI (red band) by gestational age (longitudinal model). Trajectories of individual studies are also shown (thin lines)

Fig. 3
figure 3

Mean heart rate (solid black line), with 95% CI (red band) by gestational age (longitudinal model). Trajectories of individual studies are also shown (thin lines)

Forest plots of systolic, diastolic and heart rate data (one plot per trimester) are shown (Additional file 2: Figure S2). Significant heterogeneity was present for all measures in all trimesters. Blood pressure and heart rate mean trimester estimates were similar whether estimated using our longitudinal model or random effects meta-analyses (Additional file 2: Table S5).

Subgroup analyses

Studies that used a manual measurement reported higher mean diastolic blood pressures than studies using an automated technique, difference (95% CI) in mean intercept of 4.9 (0.8, 8.9) mmHg (p = 0.020). Mean manual systolic blood pressure measurements did not differ from those in studies that used an automated measurement, difference (95% CI) in mean intercept of 2.8 (− 2.3, 7.9), p = 0.274 (Additional file 2: Figure S3).

Studies of automated measures commenced in 2002 becoming more common over time. We therefore analysed the effect of time on blood pressure for manual measurements only. Each year from 1969 to 2017, diastolic blood pressure increased by 0.26 (95% CI 0.10–0.43) mmHg, p = 0.003. Systolic blood pressure rose by 0.12 (95% CI − 0.09, 0.33) mmHg per annum, but the rise was not statistically significant (p = 0.256). Differences were not affected by gestational age.

Data was available from studies to allow us to assess the effects of parity on systolic and diastolic blood pressure. Nulliparous and parous women did not differ in either systolic blood pressure, mean (95% CI) difference − 0.32 (− 7.7, 7.1) mmHg, p = 0.927, or diastolic blood pressure, mean (95% CI) difference 1.30 (− 5.2, 7.8) mmHg, p = 0.671, (Additional file 2: Figure S4).

We could not adjust for maternal characteristics, such as age and weight, as such data were often missing or reported using different summary measures at different gestational ages.

Sensitivity analyses

Excluding outlying studies (with means lying outside of the predictive interval) reduced the number of studies by a maximum of five studies for studies of blood pressure. As all the outlying studies were “high outliers”, the mean estimates of systolic and diastolic blood pressure were decreased by about 1 mmHg, but the pattern across gestational ages remained the same (Additional file 2: Table S5b). This analysis also removed the one relatively small study where blood pressure appeared to decrease toward the end of pregnancy [49]. No studies of heart rate had means outlying the predictive interval.

Analysing only studies with a quality score above 50% reduced the number of studies for analysis from 34 to 12 for blood pressure and from 13 to 7 for heart rate. We found little change in mean estimates of blood pressure (though systolic blood pressure fell marginally in trimester 2), or heart rate, and measures of heterogeneity remained above 95% (Additional file 2: Table S5c).

Discussion

Our study synthesises the available evidence to describe changes in blood pressure and heart rate during pregnancy. As far as we are aware, this has not previously been done. We show that systolic blood pressure rises by 5.6 (95% CI 4.0, 7.2) mmHg between 10 and 40 weeks gestation (with a possible slight drop of around 1 mmHg in trimester 2 when only higher-quality studies were included). Unlike systolic blood pressure, diastolic blood pressure is lowest at 21 weeks gestation, rising by 6.9 (CI 6.2, 7.5) mmHg by 40 weeks. Mean diastolic blood pressures were on average 4.9 (0.8, 8.9) mmHg lower when measured using automated techniques than when using manual methods. There is no difference in either systolic or diastolic blood pressure between nulliparous and parous women. Over 48 years, average diastolic blood pressures rose by 0.26 (95% CI 0.10–0.43) mmHg per year. Heart rate rises by 7.6 (95% CI 1.8–13.4) beats per minute through pregnancy.

Our synthesis brings together more blood pressure and heart rate data from more pregnant women than has previously been done. This increases our understanding of the trends that occur during pregnancy. It also shows the large between-study heterogeneity, emphasising the importance of not simply taking results from a single study. Consequently, our mean estimates were imprecise (95% CI width was around 5 mmHg for blood pressure and 9 beats per minute for heart rate). We did not meta-analyse other centile estimates for blood pressure and heart rate (for example 5th or 95th). As most studies did not report centiles of the distributions, approximations would need to be made, using assumptions about data distributions. The precision would likely have been lower than at the means, resulting in wide confidence intervals, with little clinical value. Such an analysis would have been imprecise and potentially misleading.

As with many meta-analyses, combining these data is complex. Included studies were of mixed methodological quality. We identified three aspects of particular concern: Firstly, a lack of accuracy in measuring and reporting of gestational age. Secondly, only a minority of studies reported using automated blood pressure measurement devices ratified for use in pregnancy. This means that we cannot ascertain whether the differences between blood pressures measured with manual sphygmomanometers and automatic methods would have been present if automatic methods ratified for use in pregnancy had been used. Thirdly, many studies insufficiently defined the population studied. These methodological weaknesses may have contributed to the range of possible mean blood pressures for any gestational age in our analyses. They may also partly account for the heterogeneity we found. Sensitivity analyses to account for quality and outlying studies had little effect in reducing heterogeneity. Further exploration of the sources of the heterogeneity was prevented by a lack of consistent reporting of the additional variables that would be required. The substantial between-study difference in blood pressure and heart rates at all gestational ages creates uncertainty around our mean values, but is less of a problem when analysing trends across pregnancy and time and when considering differences between measurement methods.

We investigated the effect of methodological quality in two ways, by undertaking a pre-specified analysis excluding outlying studies and by excluding studies scoring less than 50% on quality assessment. As all the outlying studies were “high outliers”, the mean estimates of systolic and diastolic blood pressure were decreased by about 1 mmHg, but the pattern across gestational ages remained the same (Additional file 2: Table S5b). Excluding studies with a quality assessment score of less than 50% had little change in mean estimates of blood pressure (though systolic blood pressure fell marginally in trimester 2), or heart rate (Additional file 2: Table S5c).

We planned to estimate blood pressure and heart rate trends for normal pregnancies, accepting that definitions of normal pregnancy vary. Where participants subsequently developed complications, we included their readings. As a consequence, we kept in women who developed pre-eclampsia or gestational hypertension whilst in the original study. As most studies did not present data excluding these participants, we could not derive mean values for populations who remained “normal” at delivery.

We combined longitudinal and cross-sectional study data. Blood pressures from longitudinal studies are not independent, in contrast to cross-sectional studies where blood pressures from different women at different points in pregnancy are independent. To avoid underestimating the precision of our estimates by ignoring the longitudinal correlations, we used the random time-effects method proposed by Ishak et al. for the meta-analysis of summary data. This model addresses the dependencies between longitudinal data points through the inclusion of random time effects between studies. Additionally, the random time-effects method accounts for the exact measurement time points of the included studies. We could not include within-study correlations as none of the included studies reported these. Maternal age and weight were often not presented, and where presented, the gestational age at which they were reported was inconsistent, preventing exploration of their effect on the temporal increase in diastolic blood pressure. The included studies came from a wide range of countries (Additional file 2: Table S4), including a wide range of ethnicities. However, our results may not be generalisable across all ethnic groups. Given the large number of included patients, it appears unlikely that our pre-specified plan to exclude studies with less than 50 participants significantly affected our findings.

Our findings remain compatible with the known increase in myocardial alpha receptors (resulting in increased heart rate), increased plasma volume and decreased systemic vascular resistance that occur in pregnancy [9]. However, in comparison to the 5-mmHg mid-pregnancy drop for systolic blood pressure and 10–15-mmHg drop for diastolic blood pressure previously suggested [7,8,9], the changes we found were small (with little change in systolic blood pressure and a 2–3-mmHg drop in diastolic blood pressure). It is possible that blood pressure drops in pregnancy before most of the included studies took measurements [42, 70]. However, our lowest mean systolic and diastolic blood pressures were similar to those reported for normal young, non-pregnant female populations [71] and a study used as evidence of an early drop is included in our model [42]. Heart rate rose by 7.6 (95% CI 1.8, 13.4) beats/min rather than the 10–20 beats/min core texts commonly suggest [7,8,9]. Taken with other work showing smaller changes than previously though [38, 43, 51], these findings should alter current teaching, allowing more reliable assessment of pregnant women. Previous work in adult early warning scores shows that relatively small changes in thresholds have large changes in the ability of a score to detect deterioration [13, 14]. Published maternal early warning scores commonly have ranges for alerting thresholds of 10 mmHg for blood pressure and 10 beats per minute for heart rate [11, 72]. Our study shows that the normal changes in pregnancy account for over half these ranges. It seems likely that detection of acute deterioration in pregnancy could be improved by taking account of gestation. Equally, recognition of women at risk of hypertensive disorders of pregnancy may be improved by taking account of these patterns [73]. Prior to our study, possibly the best evidence for blood pressure patterns in pregnancy came from a single-centre study undertaken over 20 years ago [38]. Data from this work contributes to our study. The evidence for patterns in heart rate was even more limited. Blood pressure differences between nulliparous and parous women were small, in line with previous findings [38], and did not reach statistical significance.

Our finding of increasing diastolic blood pressure over the 48 years in which these studies have been undertaken is previously unknown. We did not find a study with data over a sufficient period to add to this finding. Increasing average maternal age [74,75,76] and/or weight [38, 77] may provide part of the explanation. These changes contribute to the uncertainty of our overall estimates.

The mean diastolic blood pressure was lower when measured using automated methods than when measured manually. Previously, several automated monitors have been found to underestimate diastolic blood pressure in pre-eclampsia [78,79,80]. Although we included women who subsequently developed pre-eclampsia, their contribution to our overall effect will be small as they form a small proportion of the total cohort and contributed readings prior to developing pre-eclampsia. Importantly, the mean difference is just lower than the minimum validation requirement for automated devices, suggesting that many of the devices used would not achieve this criteria [81]. The difference between manual and automated measurement could commonly change the weight applied to a blood pressure measurement in early warning scores. As many of the automated techniques were not known to be certified for use in pregnancy and several automated devices have been validated for use in pregnancy [82,83,84,85], it may be that the problem could be resolved by only using certified devices. Alternatively, the difference may in part be explained by use of the fourth rather than fifth phase to determine diastolic pressure manually.

Future studies should define gestational age precisely, recruit well-defined populations and for blood pressure only use devices ratified for use in pregnancy. For blood pressure, the differences between automated and manual methods across pregnancy need exploring with automated methods approved for use in pregnancy. The changes in diastolic blood pressure across five decades suggest normal ranges should be regularly revisited. Finally, the impact of using gestation-specific centiles to allow earlier detection of the unwell mother requires investigation.

Conclusions

Gestational changes in blood pressure and heart rate should be taken into account when assessing pregnant women, but heterogeneity between studies prevents the production of gestation-specific evidence-based normal ranges. Assessment of blood pressure need not differ between nulliparous and parous women. Automatically measured diastolic blood pressures are lower than those measured manually. A consistent measurement system should be used through pregnancy. Decreases in blood pressure mid-pregnancy and increases in heart rate through pregnancy are smaller than previously thought. Taken with other work, these findings should contribute to more reliable assessment of pregnant women. Increases in diastolic blood pressures recorded over the last half century show contemporary data is required to define normal ranges for current practice.

Availability of data and materials

All data generated or analysed during this study are included in this published article (and its supplementary information files).

Abbreviations

AIC:

Akaike Information Criterion

BIC:

Bayesian Information Criterion

BMI:

Body mass index

BP:

Blood pressure

CI:

Confidence interval

ECG:

Electrocardiography

MEOWS:

Modified Early Obstetric Warning Score

ML:

Maximum likelihood

MOOSE:

Meta-analysis Of Observational Studies in Epidemiology

PRISMA:

Preferred Reporting Items for Systematic Reviews and Meta-Analyses

QUADAS-2:

Quality Assessment of Diagnostic Accuracy Studies 2

REML:

Restricted maximum likelihood estimation

References

  1. Swanton RDJ, Al-Rawi S, Wee MYK. A national survey of obstetric early warning systems in the United Kingdom. Int J Obstet Anesth. 2009;18:253–7.

    Article  CAS  PubMed  Google Scholar 

  2. Smith GB, Isaacs R, Andrews L, Wee MY, van Teijlingen E, Bick DE, et al. Vital signs and other observations used to detect deterioration in pregnant women: an analysis of vital sign charts in consultant-led UK maternity units. Int J Obstet Anesth. 2017;30:44–51.

    Article  CAS  PubMed  Google Scholar 

  3. Paterson-Brown S, Howell C. Managing Obstetric Emergencies and Trauma (MOET): Course manual. Cambridge: Cambridge University Press; 2014.

  4. Isaacs RA, Wee MYK, Bick DE, Beake S, Sheppard ZA, Thomas S, et al. A national survey of obstetric early warning systems in the United Kingdom: five years on. Anaesthesia. 2014;69(7):687–92.

    Article  CAS  PubMed  Google Scholar 

  5. Winter C, Crofts J, Laxton C, Barnfield S, Draycott T, editors. PRactical Obstetric Multi-Professional Training (PROMPT): course manual. Cambridge: Cambridge University Press; 2012.

  6. Chamberlain G, Pipkin F. Clinical physiology in obstetrics. 3rd ed. Oxford: Blackwell Science; 1998.

    Google Scholar 

  7. Khalil A. Your essential revision guide: MRCOG part one : the official companion to the Royal College of Obstetricians and Gynaecologists revision course, Chapter 31. Fiander A, Thilaganathan B, editors. London: Royal College of Obstetricians and Gynaecologists (Great Britain). Cambridge University Press; 2010. 538.

  8. O’Donoghue K. Obstetrics by ten teachers, chapter 3. 19th ed. Baker PN, Kenny LC, editors. London: CRC press; 2011. 436 p.

  9. Blackburn ST. Maternal, fetal, & neonatal physiology: a clinical perspective, chapter 9. 4th ed. Philadelphia: Elsevier Saunders; 2013. 719 p.

    Google Scholar 

  10. Wilson M, Morganti AA, Zervoudakis I, Letcher RL, Romney BM, Von Oeyon P, et al. Blood pressure, the renin-aldosterone system and sex steroids throughout normal pregnancy. Am J Med. 1980;68(1):97–104.

    Article  CAS  PubMed  Google Scholar 

  11. CMACE. Saving Mothers’ Lives: Reviewing maternal deaths to make motherhood safer: 2006–2008. BJOG. 2011;118:1–203.

    Google Scholar 

  12. McGlennan AP, Sherratt K. Charting change on the labour ward. Anaesthesia. 2013;68:338–41.

    Article  CAS  PubMed  Google Scholar 

  13. Smith GB, Prytherch DR, Schmidt PE, Featherstone PI. Review and performance evaluation of aggregate weighted “track and trigger” systems. Resuscitation. 2008;77:170–9.

    Article  PubMed  Google Scholar 

  14. Smith GB, Prytherch DR, Schmidt PE, Featherstone PI, Higgins B. A review, and performance evaluation, of single-parameter “track and trigger” systems. Resuscitation. 2008;79(1):11–21.

    Article  PubMed  Google Scholar 

  15. Stroup DF, Berlin JA, Morton SC, Olkin I, Williamson GD, Rennie D, et al. Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis of observational studies in epidemiology (MOOSE) group. JAMA. 2000;283(15):2008–12.

    Article  CAS  PubMed  Google Scholar 

  16. Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group. Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement. PLoS Med. 2009;6(7):e1000097.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Loerup L, Pullon RMRM, Birks J, Fleming S, Mackillop LHLH, Watkinson PJPJ. Trends of vital signs with gestational age in normal pregnancies: a systematic review protocol. BMJ Open. 2016;6(1):e008769.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Whiting PF, Rutjes AWS, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529–36.

    Article  PubMed  Google Scholar 

  19. Ioannou C, Talbot K, Ohuma E, Sarris I, Villar J, Conde-Agudelo A, et al. Systematic review of methodology used in ultrasound studies aimed at creating charts of fetal size. BJOG. 2012;119(12):1425–39.

    Article  CAS  PubMed  Google Scholar 

  20. Tarassenko L, Clifton DADA, Pinsky MRMR, Hravnak MTMT, Woods JRJR, Watkinson PJPJ. Centile-based early warning scores derived from statistical distributions of vital signs. Resuscitation. 2011;82(8):1013–8.

    Article  PubMed  Google Scholar 

  21. United Nations Development Programme. Human Development Report 2015. New York: Work for Human Development; 2015.

  22. Butt K, Lim K, Bly S, Cargill Y, Davies G, Denis N, et al. Determination of gestational age by ultrasound. J Obstet Gynaecol Canada. 2014;36(2):171–81.

    Article  Google Scholar 

  23. Wartolowska KA, Gerry S, Feakins BG, Collins GS, Cook J, Judge A, et al. A meta-analysis of temporal changes of response in the placebo arm of surgical randomized controlled trials: an update. Trials. 2017;18(1):323. https://doi.org/10.1186/s13063-017-2070-9.

  24. Ishak KJ, Platt RW, Joseph L, Hanley JA, Caro JJ. Meta-analysis of longitudinal studies. Clin Trials. 2007;4(5):525–39.

    Article  PubMed  Google Scholar 

  25. Brown H, Prescott R, editors. Applied mixed models in medicine, 3rd Edition. Chichester: Wiley; 2014.

  26. Yao YC. Estimating the number of change-points via Schwarz’ criterion. Stat Probab Lett. 1988;6(3):181–9.

    Article  Google Scholar 

  27. Akaike H. A new look at the statistical model identification. IEEE Trans Autom Control. 1974;19(6):716–23.

    Article  Google Scholar 

  28. Moser EB. Repeated measures modeling with PROC MIXED. SAS Users Gr Int. 2004;29(1):1–19.

    Google Scholar 

  29. Royal College of Obstetricians and Gynaecologists. Medical terms explained [Internet]. [cited 2019 Mar 25]. Available from: https://www.rcog.org.uk/en/patients/medical-terms/#t

  30. Riley RD, Higgins JPT, Deeks JJ. Interpretation of random effects meta-analyses. BMJ. 2011;342(7804):d549.

    Article  PubMed  Google Scholar 

  31. Demidov VN. Comparative evaluation of the changes in the cardiac activity and hemodynamics of healthy women at the end of pregnancy while lying on their sides and on their backs. Vopr Okhr Materin Det. 1978;23(3):71–5.

    CAS  PubMed  Google Scholar 

  32. Andreas M, Kuessel L, Kastl SP, Wirth S, Gruber K, Rhomberg F. Bioimpedance cardiography in pregnancy: a longitudinal cohort study on hemodynamic pattern and outcome. BMC Pregnancy Childbirth. 2016;16(1):128.

    Article  PubMed  PubMed Central  Google Scholar 

  33. Bakker R, Steegers EA, Mackenbach JP, Hofman A, Jaddoe VW. Maternal smoking and blood pressure in different trimesters of pregnancy: the generation R study. J Hypertens. 2010;28:2210–8.

    Article  CAS  PubMed  Google Scholar 

  34. Khan G, Ishrat N, Sabzposh N. Blood pressure patterns in pregnant women of different body mass index in three trimesters of pregnancy. Indian J Public Heal Res Dev. 2013;4(3):98–102.

    Article  Google Scholar 

  35. Lauszus FF, Rosgaard A, Lousen T, Rasmussen OW, Klebe TM, Klebe JG. Precision, consistency, and reproducibility of blood pressure in diabetic and non-diabetic pregnancy: the appraisal of repeated measurements. Acta Obstet Gynecol Scand. 2007;86(9):1063–70.

    Article  PubMed  Google Scholar 

  36. Lee P-C, Talbott EO, Roberts JM, Catov JM, Bilonick RA, Stone RA, et al. Ambient air pollution exposure and blood pressure changes during pregnancy. Environ Res. 2012;117:46–53.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  37. Lo C, Taylor RS, Gamble G, McCowan L, North RA. Use of automated home blood pressure monitoring in pregnancy: is it safe? Am J Obstet Gynecol. 2002;187(5):1321–8.

    Article  PubMed  Google Scholar 

  38. Macdonald-Wallis C, Silverwood RJ, Fraser A, Nelson SM, Tilling K, Lawlor DA, et al. Gestational-age-specific reference ranges for blood pressure in pregnancy: findings from a prospective cohort. J Hypertens. 2015;33(1):96–105.

    Article  CAS  PubMed  Google Scholar 

  39. MacGillivray I, Rose GA, Rowe B. Blood pressure survey in pregnancy. Clin Sci. 1969;37(2):395–407.

    CAS  PubMed  Google Scholar 

  40. Matkin CC, Britton J, Samuels S, Eskenazi B. Smoking and blood pressure patterns in normotensive pregnant women. Paediatr Perinat Epidemiol. 1999;13(1):22–34.

    Article  CAS  PubMed  Google Scholar 

  41. Miller RS, Thompson ML, Williams MA. Trimester-specific blood pressure levels in relation to maternal pre-pregnancy body. Paediatr Perinat Epidemiol. 2007;21(6):487–94.

    Article  PubMed  Google Scholar 

  42. Mahendru AA, Everett TR, Wilkinson IB, Lees CC, McEniery CM. A longitudinal study of maternal cardiovascular function from preconception to the postpartum period. J Hypertens. 2014;32(4):849–56.

    Article  CAS  PubMed  Google Scholar 

  43. Nama V, Antonios TF, Onwude J, Manyonda IT. Mid-trimester blood pressure drop in normal pregnancy: myth or reality? J Hypertens. 2011;29(4):763–8.

    Article  CAS  PubMed  Google Scholar 

  44. Churchill D, Beevers DG. Differences between office and 24-hour ambulatory blood pressure measurement during pregnancy. Obstet Gynecol. 1996;88(3):455–61.

    Article  CAS  PubMed  Google Scholar 

  45. Okonofua FE, Balogun JA, Amiengheme NA, O’Brien SPM. Blood pressure changes during pregnancy in Nigerian women. Int J Cardiol. 1992;37(3):373–9.

    Article  CAS  PubMed  Google Scholar 

  46. Peterson CM, Jovanovic-Peterson L, Mills JL, Conley MR, Knopp RH, Reed GF, et al. The diabetes in early pregnancy study: changes in cholesterol, triglycerides, body weight, and blood pressure. The National Institute of Child Health and Human Development--the diabetes in early pregnancy study. Am J Obstet Gynecol. 1992;166(2):513–8.

    Article  CAS  PubMed  Google Scholar 

  47. Strevens H, Wide-Swensson D, Ingemarsson I. Blood pressure during pregnancy in a Swedish population; impact of parity. Acta Obs Gynecol Scand. 2001;80(9):824–9.

    Article  CAS  Google Scholar 

  48. Grindheim G, Estensen ME, Langesaeter E, Rosseland L, Toska K. Changes in blood pressure during healthy pregnancy: a longitudinal cohort study. J Hypertens. 2012;30(2):342–50.

    Article  CAS  PubMed  Google Scholar 

  49. Halligan A, O’Brien E, O’Malley K, Mee F. Twenty-four-hour ambulatory blood pressure measurement in a primigravid population. J Hpertension. 1993;11:869–73.

    Article  CAS  Google Scholar 

  50. Hilmert CJ, Schetter CD, Dominguez TP, Abdou C, Hobel CJ, Glynn L, et al. Stress and blood pressure during pregnancy: racial differences and associations with birthweight. Psychosom Med. 2008;70(1):57–64.

    Article  PubMed  Google Scholar 

  51. Ishikuro M, Obara T, Metoki H, Ohkubo T, Yamamoto M, Akutsu K, et al. Blood pressure measured in the clinic and at home during pregnancy among nulliparous and multiparous women: the BOSHI study. Am J Hypertens. 2013;26(1):141–8.

    Article  PubMed  Google Scholar 

  52. Iwasaki R, Ohkuchi A, Furuta I, Ojima T, Matsubara S, Sato I, et al. Relationship between blood pressure level in early pregnancy and subsequent changes in blood pressure during pregnancy. Acta Obstet Gynecol Scand. 2002;81(10):918–25.

    Article  PubMed  Google Scholar 

  53. Jasovic-Siveska E, Jasovic V. Prediction of mild and severe preeclampsia with blood pressure measurements in first and second trimester of pregnancy. Ginekol Pol. 2011;82(11):845–50.

    PubMed  Google Scholar 

  54. Kac G, Mendes RH, Farias DR, Eshriqui I, Rebelo F, Benaim C, et al. Hepatic, renal and inflammatory biomarkers are positively associated with blood pressure changes in healthy pregnant women: a prospective cohort. Medicine (Baltimore). 2015;94(20):e683.

    Article  CAS  Google Scholar 

  55. Amoakoh-Coleman M, Ogum-Alangea D, Modey-Amoah E, Yao Ntumy M, Adanu R, Oppong S. Blood pressure patterns and body mass index status in pregnancy: an assessment among women reporting for antenatal care at the Korle-Bu teaching hospital. Ghana PLoS One. 2017;12(12):e0188671.

    Article  PubMed  CAS  Google Scholar 

  56. Veerabhadrappa ST, Vyas AL, Anand S. Changes in heart rate variability and pulse wave characteristics during normal pregnancy and postpartum. Int J Biomed Eng Technol. 2015;17(2):99.

    Article  Google Scholar 

  57. Ekholm E, Erkkolab R, Hartiala J. Comparison of cardiovascular reflex tests and blood pressure measurement in prediction of pregnancy-induced hypertension. Eur J Obstet Gynecol Reprod Biol. 1994;54:37–41.

    Article  CAS  PubMed  Google Scholar 

  58. Elvan-Taşpinar A, Uiterkamp L, Sikkems JM, Bots ML, Koomans HW, Bruinse HA, et al. Validation and use of the Finometer™ for blood pressure measurement in normal, hypertensive and pre-eclamptic pregnancy. J Hypertens. 2003;21(11):2053–60.

    Article  PubMed  Google Scholar 

  59. Foo FL, Collins A, McEniery CM, Bennett PR, Wilkinson IB, Lees CC. Preconception and early pregnancy maternal haemodynamic changes in healthy women in relation to pregnancy viability. Hum Reprod. 2017;32(5):985–92.

    Article  CAS  PubMed  Google Scholar 

  60. Ngan Kee WD, Shaw K, Ng FF, Karmakar MK, Critchley LA, Gin T. A prospective comparison of vasopressor requirement and hemodynamic changes during spinal anesthesia for cesarean delivery in patients with multiple gestation versus singleton pregnancy. Anesth Analg. 2007;104:407–11.

    Article  PubMed  CAS  Google Scholar 

  61. Ochsenbein-Kolble N, Roos M, Gasser T, Huch R, Huch A, Zimmermann R. Cross sectional study of automated blood pressure measurements throughout pregnancy. BJOG An Int J Obstet Gynaecol. 2004;111(4):319–25.

    Article  CAS  Google Scholar 

  62. Tape TG, Rayburn WF, Bremer KD, Schnoor TA. Ambulatory blood pressure monitoring during pregnancy with a new, small, easily concealed monitor. J Reprod Med. 1994;39(12):968–72.

    CAS  PubMed  Google Scholar 

  63. Tuffnell DJ, Buchan PC, Albert D, Tyndale-biscoe S. Fetal heart rate responses to maternal exercise, increased maternal temperature and maternal circadian variation. J Obstet Gynaecol. 1990;10(5):387–91.

    Article  Google Scholar 

  64. Van Der Graaf AM, Zeeman GG, Groen H, Roberts C, Dekker GA. Non-invasive assessment of maternal hemodynamics in early pregnancy. Pregnancy Hypertens. 2013;3(4):261–9.

    Article  PubMed  Google Scholar 

  65. Gu H, Zhang S, Qiao Y, Luo Z, Zeng Y, Wang Q. A study of maternal hemodynamic change during healthy pregnancy and women with gestation hypertension. Biomed Mater Eng. 1991;16(1):77–82.

    Google Scholar 

  66. van Oppen ACC, Van Der Tweel I, Alsbach GPJ, Heethaar RM, Bruinse HW. A longitudinal study of maternal hemodynamics during normal pregnancy. Obstet Gynecol. 1996;88(96):40–6.

    PubMed  Google Scholar 

  67. Carpenter R, D’Silva L, Emery SJ, Ulan O, Rassi D, Lewis MJ. Changes in heart rate variability and QT variability during the first trimester of pregnancy. Physiol Meas. 2015;36:531–45.

    Article  CAS  PubMed  Google Scholar 

  68. Guy GP, Ling HZ, Machuca M, Poon LC, Nicolaides KH. Effect of change in posture on maternal functional hemodynamics at 35–37 weeks’ gestation. Ultrasound Obstet Gynecol. 2018;51(3):368–74.

    Article  CAS  PubMed  Google Scholar 

  69. Turan OM, De Paco C, Kametas N, Khaw A, Nicolaides KH. Effect of parity on maternal cardiac function during the first trimester of pregnancy. Ultrasound Obstet Gynecol. 2008;32(7):849–54.

    Article  CAS  PubMed  Google Scholar 

  70. Sanghavi M, Rutherford JD. Cardiovascular physiology of pregnancy. Circulation. 2014;130(12):1003–8.

    Article  PubMed  Google Scholar 

  71. Wright JD, Hughes JP, Ostchega Y, Yoon SS, Nwankwo T. Mean systolic and diastolic blood pressure in adults aged 18 and over in the United States, 2001–2008. Natl Health Stat Report. 2011;35:1-22, 24

  72. The Irish Maternity Early Warning System (IMEWS) [Internet]. 2014 [cited 2017 Dec 4]. Available from: http://www.hse.ie/eng/about/Who/clinical/natclinprog/obsandgynaeprogramme/imews

  73. Macdonald-Wallis C, Lawlor DA, Fraser A, May M, Scott M. Blood pressure change in normotensive, gestational hypertensive, preeclamptic and essential hypertensive pregnancies. Hypertension. 2012;59(6):1241–8.

    Article  CAS  PubMed  Google Scholar 

  74. Mills M, Rindfuss RR, McDonald P, te Velde E. Why do people postpone parenthood? Reasons and social policy incentives. Hum Reprod Update. 2011;17(6):848–60.

    Article  PubMed  PubMed Central  Google Scholar 

  75. Office for National Statistics. Live births in England and Wales by characteristics of mother 1: 2013. Stat Bull. 2014;(November):1–10. https://www.ons.gov.uk/peoplepopulationandcommunity/birthsdeathsandmarriages/livebirths/bulletins/livebirthsinenglandandwalesbycharacteristicsofmother1/2014-10-16.

  76. Matthews TJ, Hamilton BE. First births to older women continue to rise. NCHS Data Brief. 2014;152:1–8.

    Google Scholar 

  77. Heslehurst N, Rankin J, Wilkinson JRR, Summerbell CDD. A nationally representative study of maternal obesity in England, UK: trends in incidence and demographic inequalities in 619 323 births, 1989-2007. Int J Obes. 2010;34(3):420–8.

    Article  CAS  Google Scholar 

  78. Gupta M, Shennan AH, Halligan A, Taylor DJ, de Swiet M. Accuracy of oscillometric blood pressure monitoring in pregnancy and pre-eclampsia. BJOG. 1997;104(3):350–5.

    Article  CAS  Google Scholar 

  79. Natarajan P, Shennan AH, Penny J, Halligan AW, de Swiet M, Anthony J. Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia. Am J Obstet Gynecol. 1999;181(5):1203–10.

    Article  CAS  PubMed  Google Scholar 

  80. Reinders A, Cuckson AC, Jones CR, Poet R, O’Sullivan G, Shennan AH. Validation of the Welch Allyn “vital signs” blood pressure measurement device in pregnancy and pre-eclampsia. BJOG. 2003;110(2):134–8.

    Article  CAS  PubMed  Google Scholar 

  81. O’ Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al. European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit. 2010;15(1):23–38.

    Article  Google Scholar 

  82. de Greeff A, Beg Z, Gangji Z, Dorney E, Shennan AH. Accuracy of inflationary versus deflationary oscillometry in pregnancy and preeclampsia: OMRON-MIT versus OMRON-M7. Blood Press Monit. 2009;14(1):37–40.

    Article  PubMed  Google Scholar 

  83. Golara M, Benedict A, Jones C, Randhawa M, Poston L, Shennan AH. Inflationary oscillometry provides accurate measurement of blood pressure in pre-eclampsia. BJOG. 2002;109(10):1143–7.

    Article  PubMed  Google Scholar 

  84. Reinders A, Cuckson AC, Lee JTM, Shennan AH. An accurate automated blood pressure device for use in pregnancy and pre-eclampsia: the Microlife 3BTO-A. BJOG. 2005;112(7):915–20.

    Article  CAS  PubMed  Google Scholar 

  85. Chung Y, de Greeff A, Shennan A. Validation and compliance of a home monitoring device in pregnancy: Microlife WatchBP Home. Hypertens Pregnancy. 2009;28(3):348–59.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We wish to thank Inessa Walker for her help with translation (Russian) and Tatjana Petrinic for her help designing and undertaking the searches.

Funding

This work was supported by the NIHR Biomedical Research Centre, Oxford. The funders had no role in study design, data collection and analysis, decision to publish or preparation of the manuscript.

Author information

Authors and Affiliations

Authors

Contributions

All authors were involved in the initial scoping of the idea and drafting the protocol. LL extracted data and wrote the first draft of the manuscript. RP extracted data and corrected the manuscript. SG and JB reviewed the data, undertook data analysis and reviewed the manuscript. SF provided content expertise and reviewed the manuscript. LM provided content expertise, with PW provided clinical expertise to facilitate accurate extraction and co-wrote the manuscript. PW conceived the idea, provided clinical expertise to facilitate accurate extraction and took the manuscript from initial draft to completion. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Peter J. Watkinson.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

PW, JB, SM and SF report significant grants from the National Institute of Health Research (NIHR), UK. PW, JB, SM, LM and SF report significant grants from the NIHR Biomedical Research Centre, Oxford, during the conduct of the study. PW and LM report modest grants and personal fees from Sensyne Health, outside the submitted work. LL and RP report significant grants from the RCUK Digital Economy Programme. LL reports significant grants from the Clarendon Fund. LL now works for the Boston Consulting Group, whose clients include medical technology and health analytics companies. PW and LM work part-time for Sensyne Health. PW and LM hold shares in Sensyne Health.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Additional files

Additional file 1:

PRISMA checklist. (DOCX 30 kb)

Additional file 2:

Exclusion diagnoses and reasons, search strategy, quality assessment criteria and results, summary of included studies, additional analyses. (DOCX 512 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Loerup, L., Pullon, R.M., Birks, J. et al. Trends of blood pressure and heart rate in normal pregnancies: a systematic review and meta-analysis. BMC Med 17, 167 (2019). https://doi.org/10.1186/s12916-019-1399-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12916-019-1399-1

Keywords